Leave Your Message
DPS3051F Smart Differential Pressure Transmitter
Differential Pressure Transmitter

DPS3051F Smart Differential Pressure Transmitter

The DPS3051F Series Smart Differential Pressure Transmitter is a state-of-the-art device designed to meet the needs of precision measurement in challenging industrial environments. Featuring an advanced monocrystalline silicon differential pressure sensor, the DPS3051F delivers exceptional performance in applications requiring high accuracy, stability, and reliability.

    Features

    ●Advanced monocrystalline silicon differential pressure sensor adopted
    ●Double-wire mode, 4~20mA analog output, HART® protocol digital communication option
    ●Intelligent LCD gauge outfit with backlight
    ●With both the remote transmission and the local zero and pressure range adjustment
    ●Complete varieties, high accuracy, good stability,
    ●Isolation ex-proof housing structure, strong resistance to the frequency conversion interference
    ●High static pressure, high overload protection
    ●Patented double overload protection diaphragm design
    ●Lightning protection circuit design

    Introduction

    The DPS3051F Series Smart Differential Pressure Transmitter is a state-of-the-art device designed to meet the needs of precision measurement in challenging industrial environments. Featuring an advanced monocrystalline silicon differential pressure sensor, the DPS3051F delivers exceptional performance in applications requiring high accuracy, stability, and reliability.

    Application

    The DPS3051F Series is ideal for applications in industries such as petrochemical, power, water treatment, and process control, where reliability, accuracy, and safety are paramount. Its innovative design and rugged features make it a trusted solution for critical differential pressure measurement tasks.

     

    Pressure type

    Differential pressure

    Pressure range

    0~10kPa…3MPa

    Power supply

    10.5VDC~36VDC(Standard 24VDC)

    Output signal

    4mA~20mA+HART protocol

    Overload pressure

    ≤200%

    Response time

    ≤10ms(10%~90%)

    Media temperature

    -40℃~85℃, -20℃~70℃ with LCD display

    Accuracy

    0.1%FS

    Measuring medium

    Fluid compatible with 304 and 316L

    Filling oil

    Silicon oil

    Distance parameter

    ≤5m

    Protection

    IP65