Leave Your Message
FMTL Series Flange Type Liquid Turbine Flow Meter
Turbine Flow Meter

FMTL Series Flange Type Liquid Turbine Flow Meter

The FMTL series liquid turbine flow meters feature high accuracy, good repeatability, simple structure, high pressure resistance, wide measurement range, compact size, lightweight, low pressure loss, long service life, simple operation, and easy maintenance. They are used for measuring the volumetric flow and cumulative volume of low viscosity, non-corrosive, and clean liquids in closed pipelines. These flow meters are widely applicable in industries such as petroleum, chemical engineering, metallurgy, organic liquids, inorganic liquids, liquefied gas, urban gas networks, pharmaceuticals, food processing, and papermaking.

    Introduction

    The FMTL series liquid turbine flow meters feature high accuracy, good repeatability, simple structure, high pressure resistance, wide measurement range, compact size, lightweight, low pressure loss, long service life, simple operation, and easy maintenance. They are used for measuring the volumetric flow and cumulative volume of low-viscosity, non-corrosive, and clean liquids in closed pipelines. These flow meters are widely applicable in industries such as petroleum, chemical engineering, metallurgy, organic liquids, inorganic liquids, liquefied gas, urban gas networks, pharmaceuticals, food processing, and papermaking.

    Working Principle

    When the measured liquid flows through the sensor, the rotor is subjected to force and begins to rotate. The rotation speed of the rotor is directly proportional to the average flow velocity in the pipeline. The rotor’s movement periodically alters the magnetic reluctance of the magnetic circuit, causing the magnetic flux in the detection coil to vary periodically. This generates an induced electromotive force with the same frequency as the rotor's rotational frequency, which is then amplified, converted, and processed.

    Features

    ◆ Available with hygienic type, food-grade flowmeter designed for measuring both conductive and non-conductive, non-corrosive liquids.  
    ◆ Excellent repeatability, with short-term repeatability ranging from 0.05% to 0.2%, offering good sensitivity and stability.  
    ◆ Operating temperature range: -20°C to 120°C;  -20°C to 130°C optional.  
    ◆ Suitable for mediums with a viscosity less than 5×10⁻⁶ m²/s.  
    ◆ Wide measurement range: medium and large diameters up to 1:20, small diameters up to 1:10.  
    ◆ Optional battery powered.  
    ◆ Available in an insert-type design, ideal for large-diameter measurements, with continuous removal capability for easy installation and maintenance.

    Measuring medium

    No impurities, low viscosity, no strong corrosive liquid

    Nominal Diameter(mm)

    DN15-DN200 ( Flange connection)

    DN4-DN80 (Thread connection)

    DN4-DN200 (Clamp connection)

    Accuracy

    ±1%R, ±0.5%R, ±0.2% R(Customized)

    Measurement Range Rate

    1:10,1:15,1:20

    Connection method

    Flange, Thread, Clamp, Hygienic, Insert

    Instrument material

    304 stainless steel, 316L stainless steel

    Medium Temperature(℃)

    -20 ~ +120 ℃

    Ambient Conditions

    Temperature:-10~+55℃,

    Relative Humidity:5%~90%

    Atmosphere Pressure:86~106Kpa

    Output Signal

    Pulse, 4~20mA

    Power Supply

    Sensor: +12V DC, +24V DC (option)

    Transducer: +24V DC

    Scene display type meter: 3.2V Lithium

    Signal Transmission Line

    STVPV 3×0.3 (three wires), 2×0.3(two wires)

    Transmission Distance

    ≤1000m

    Signal Line Interface

    Internal thread M20×1.5

    Explode-proof Class

    ExdIIBT6

    Protection Class

    IP65